Introduction and Planning Guide
The IBM 2212 ships with unpopulated adapter slots. You can customize
it to meet your needs with the PMC and CPCI adapters listed in this
section.
With one CPCI adapter slot each, Models 10F, 15F, 10H, and 15H are suited
for well-defined connectivity opportunities requiring only one CPCI
adapter.
With four CPCI adapter slots each, Models 40F, 45F, 40H, and 45H offer
scalable support for your network as it expands.
You can order the following adapters for the IBM 2212:
Table 2-2. IBM 2212 Adapters, Feature Codes, and Part Numbers
CPCI adapter options
|
4-Port WAN CPCI
| 3103
| 85H8836
| "4-Port WAN CPCI Adapter (FC 3103, PN 85H8836)"
|
2-Port ISDN BRI-U CPCI
| 3104
| 85H4725
| "2-Port ISDN BRI-U CPCI Adapter (FC 3104, PN 85H4725)"
|
2-Port ISDN BRI-S/T CPCI
| 3105
| 85H4726
| "2-Port ISDN BRI-S/T CPCI Adapter (FC 3105, PN 85H4726)"
|
1-Port ISDN PRI T1/J1 CPCI
| 3106
| 85H4727
| "1-Port ISDN PRI (T1/J1) CPCI Adapter (FC 3106, PN 85H4727)"
|
1-Port ISDN PRI E1 CPCI
| 3107
| 85H4728
| "1-Port ISDN PRI (E1) CPCI Adapter (FC 3107, PN 85H4728)"
|
2-Port ISDN PRI T1/J1 CPCI
| 3108
| 85H4680
| "2-Port ISDN PRI T1/J1 CPCI Adapter (FC 3108, PN 85H4680)"
|
2-Port ISDN PRI E1 CPCI
| 3109
| 85H4682
| "2-Port ISDN PRI E1 CPCI Adapter (FC 3109, PN 85H4682)"
|
2-Port Token-Ring CPCI
| 3110
| 85H4717
| "2-Port Token-Ring CPCI Adapter (FC 3110, PN 85H4717)"
|
2-Port 10/100 Ethernet CPCI
| 3111
| 85H4735
| "2-Port 10/100-Mbps CPCI Ethernet Adapter (FC 3111, PN 85H4735)"
|
2-Port Analog FXS Voice/Fax CPCI
| 3210
| 85H8828
| "2-Port Analog FXS Voice/Fax CPCI (FC 3210, PN 85H8828)"
|
2-Port Analog FXO Voice/Fax CPCI
| 3211
| 02L2398
| "2-Port Analog FXO Voice/Fax CPCI (FC 3211, PN 02L2398)"
|
2-Port Analog E&M Voice/Fax CPCI
| 3212
| 02L2400
| "2-Port Analog E&M Voice/Fax CPCI (FC 3212, PN 02L2400)"
|
4-Port Analog 56K Modem CPCI
| 3213
| 85H8831
| "4-Port Analog 56K Modem CPCI (FC 3213, PN 85H8830)"
|
Compression/Encryption CPCI Adapter
| 3215
| 85H4732
| "Compression/Encryption CPCI Adapter (FC 3215, PN 85H4732)"
|
|
|
|
|
CPCI adapter options available for Models 4xx only:
|
T1/J1 24-channel Digital Modem Adapter
| 3201
| 85H8812
| "T1/J1 24 Channel Digital Modem Adapter (FC 3201, PN 85H8812)"
|
T1/J1 12-channel Digital Modem Adapter
| 3202
| 35H2262
| "T1/J1 12-Channel Digital Modem Adapter (FC 3202, PN 35H2262)"
|
E1 30-channel Digital Modem Adapter
| 3204
| 25L5606
| "E1 30-Channel Digital Modem Adapter (FC 3204, PN 25L5606)"
|
E1 12-channel Digital Modem Adapter
| 3205
| 35L2263
| "E1 12-Channel Digital Modem Adapter (FC 3205, PN 35L2263)"
|
If you have a standard system card you can also order the following
additional options for the IBM 2212:
- 32-MB DRAM SIMM (FC 3132, PN 85H4408)
- 64-MB DRAM SIMM (FC 3133, PN 85H4409)
- Hard drive (FC 3130, PN 85H4715) to make a compact flash model into a hard
drive model
If you have a high-performance system card you can also order the following
additional options for the IBM 2212:
- 64-MB EDO DRAM DIMM (FC 3233, PN 44L2537)
- 128-MB EDO DRAM DIMM (FC 3234, PN 44L2539)
- 256-MB EDO DRAM DIMM (FC 3235, PN 44L2541)
- Hard drive (FC 3130, PN 85H4715) to make a compact flash model into a hard
drive model
Note: | The IBM 2212 allows a hard drive or compact flash option; not both.
|
Provides for one attachment to a 4- or 16-Mbps Token-Ring LAN wired with
100-ohm twisted-pair cable using RJ-45 connectors. For attachment to
150-ohm wiring systems, an impedance converter such as IBM PN 73G8315 must be
used. Cable FC 2391 (PN 41H9082) is available for this adapter.
This adapter plugs into the PMC adapter slot on the system card.
Note: | Total cable length to the attaching device is limited to 100 m (328 ft) and
is for indoor use, only.
|
Provides one port for 10/100-Mbps Ethernet connections using an RJ-45
connector. This attachment provides:
- 2-KB entry hardware Transparent Bridging
- IEEE 802.3 10-Mbps Ethernet
- IEEE 802.3u 100-Mbps Ethernet
It plugs into the PMC adapter slot on the system card. Cable FC 2391
(PN 41H9082) is available for this adapter.
Each port of the 4-port WAN CPCI adapter, 4-port WAN PMC adapter, and
integrated WAN ports supports any of the following interfaces and speeds and
complies with the respective interface standard:
- EIA 232D/V.24
- 2400 bps to 115.2 Kbps
- V.35
- 9600 bps to 6.312 Mbps is supported with external clocking5 and 9600 bps to 2.048 Mbps is supported with internal
clocking.
- V.36
- 9600 bps to 6.312 Mbps is supported with external clocking5 and 9600 bps to 2.048 Mbps is supported with internal
clocking.
- X.21
- 2400 bps to 6.312 Mbps is supported with external clocking5 and 2400 bps to 2.048 Mbps is supported with internal
clocking.
The optional CPCI adapter, the integrated WAN ports on the IBM 2212
standard system card, and the 4-port WAN PMC adapter for the high-performance
system card support the 8 cables listed under "WAN cables" in Cables.
The optional adapter plugs into any 3U CPCI adapter slot. (For more
information about CPCI dimensions, see CPCI Adapter Specifications).
Provides a 2-wire U interface per port for North America. Uses an
RJ-45 connector. Support for cable FC 2391 (PN 41H9082).
This adapter plugs into any 3U CPCI adapter slot.
Provides a 4-wire S/T interface per port. Uses an RJ-45
connector.
This adapter requires cable FC 2391 (PN 41H9082), except in Australia,
where it requires cable FC 2318 (PN 86H0774).
Note: | Requires an external network termination (NT-1) for connections in North
America.
|
This adapter plugs into any 3U CPCI adapter slot.
Provides one attachment to an ISDN Primary Rate service at T1/J1
speed.
Note: | This can also be used for channelized or fractional T1/J1 support.
|
This attachment provides:
- Support for T1/J1 line speed of 1.544 Mbps.
- Twenty-three 64-Kbps B-channels for data and one 64-Kbps D-channel for
signaling, or twenty-four 64-Kbps time slots (24 DS0s) for channelized
service.
- Selectable framing to D4 (SF) format.
- Detection and generation of yellow and blue alarms.
- Facility Data Link (FDL) support.
- Generation of DSX-1 and CSU line build outs.
- Generation and detection of CSU loop codes.
- Line error counters for BPV, CV, CRC6, and framing-bit errors.
- Monitoring and enforcing of ANSI ones density requirement.
- B8ZI and AMI line coding.
- RJ-45 female connector.
- Support for cables FC 2391 (PN 41H9082) and for Japan FC 2323 (PN
30L6523).
- Two separate loopbacks for testing: payload and line. The
diagnostics program provides a local loopback, as well.
This adapter plugs into any 3U CPCI adapter slot.
Note: | This can also be used for channelized E1.
|
Provides one attachment to an ISDN Primary Rate service at E1 speed.
This attachment provides:
- Support for E1 line speed of 2.048 Mbps.
- Thirty 64-Kbps B-channels for data and one 64-Kbps D-channel for signaling
or thirty-one 64-Kbps time slots (31 DSOs) for channelized service.
- Selectable framing to FAS and CRC4 formats.
- Detection and generation of remote and AIS alarms.
- Generation of line build outs for a 120-ohm line.
- Two separate loopbacks for testing: payload and line. The
diagnostics program provides a local loopback, as well.
- Line error counters for bipolar and code violations, CRC4 code word
errors, FAS errors, and E-bits.
- B8ZI, AMI, and HDB3 line encoding.
- RJ-45 female connector.
- Support for cable FC 2324 (PN 30L6524) and in Australia for FC 2325 (PN
30L6529).
This adapter plugs into any 3U CPCI adapter slot.
Provides two ports to an ISDN Primary Rate or channelized service at T1
speed. This attachment provides the same functions as "1-Port ISDN PRI (T1/J1) CPCI Adapter (FC 3106, PN 85H4727)". It supports cables FC 2391 (PN 41H9082) and, for
Japan, FC 2323 (PN 30L6523).
This adapter plugs into any 3U CPCI adapter slot.
Provides two ports to an ISDN Primary Rate or channelized service at E1
speed. This attachment provides the same functions as "1-Port ISDN PRI (E1) CPCI Adapter (FC 3107, PN 85H4728)". It supports cables FC 2324 (PN 30L6524) and, for
Australia, FC 2325 (PN 30L6529).
This adapter plugs into any 3U CPCI adapter slot.
Provides for two attachments to 4- or 16- Mbps Token-Ring LANs wired with
100-ohm unshielded twisted-pair cable using RJ-45 connectors. For
attachment to 150-ohm Token-Ring wiring systems, an impedance converter such
as IBM PN 73G8315 must be used.
This adapter plugs into any 3U CPCI adapter slot. Cable FC 2391 (PN
41H9082) is available for this adapter.
Note: | Total cable length to the attaching device is limited to 100 m and is for
indoor use, only.
|
Provides two ports for either 10-Mbps or 100-Mbps Ethernet connections
using RJ-45 connectors. These attachments provide:
- 2-KB entry hardware Transparent Bridging
- IEEE 802.3 10-Mbps Ethernet
- IEEE 802.3u 100-Mbps Ethernet
This adapter plugs into any 3U CPCI adapter slot. Cable FC 2391 (PN
41H9082) is available for this adapter.
This adapter provides:
- Support for T1/J1 line speed of 1.544 Mbps
- Twenty-three 64-Kbps B-channels for data and one 64-Kbps D-channel for
signaling, or twenty-four 64-Kbps time slots (24 DS0s) for channelized service
- Selectable framing to D4 format for channelized and CAS support
- Selectable framing to ESF for ISDN channelized, CAS, and switch support
- Detection and generation of yellow and blue alarms
- Facility Data Link (FDL) support
- Generation of DSX-1 and CSU line build outs
- Generation and detection of CSU loop codes
- Line error counters for BPV, CV, CRC6, and framing-bit errors
- Monitoring and enforcing of ANSI ones density requirement
- B8ZI and AMI line coding
- RJ-45 female connector
- Support for cables FC 2326 (PN 30L6571) and for Japan FC 2328 (PN
30L6573).
Note: | The cable you receive with your T1/J1 Digital Modem Adapter is required for
Electromagnetic Compatibility (EMC) compliance.
|
This adapter plugs into any 6U CPCI adapter slot.
This adapter provides:
- Support for T1/J1 line speed of 1.544 Mbps
- Twenty-three 64-Kbps B-channels for data and one 64-Kbps D-channel for
signaling, or twenty-four 64-Kbps time slots (24 DS0s) for channelized service
- Selectable framing to D4 format for channelized and CAS support
- Selectable framing to ESF for ISDN channelized, CAS, and switch support
- Detection and generation of yellow and blue alarms
- Facility Data Link (FDL) support
- Generation of DSX-1 and CSU line build outs
- Generation and detection of CSU loop codes
- Line error counters for BPV, CV, CRC6, and framing-bit errors
- Monitoring and enforcing of ANSI ones density requirement
- B8ZI and AMI line coding
- RJ-45 female connector
- Support for cables FC 2326 (PN 30L6571) and for Japan FC 2328 (PN
30L6573).
Note: | The cable you receive with your T1/J1 Digital Modem Adapter is required for
Electromagnetic Compatibility (EMC) compliance.
|
This adapter plugs into any 6U CPCI adapter slot.
This adapter provides:
- Support for E1 line speed of 2.048 Mbps.
- Thirty 64-Kbps B-channels for data and one 64-Kbps D-channel for signaling
or thirty-one 64-Kbps time slots (31 DS0s) for channelized service.
- Selectable framing to FAS and CRC4 formats.
- Detection and generation of remote and AIS alarms.
- Generation of line build outs for a 120-ohm line.
- Two separate loopbacks for testing: payload and line. The
diagnostics program provides a local loopback, as well.
- Line error counters for bipolar and code violations, CRC4 code word
errors, FAS errors, and E-bits.
- B8ZI, AMI, and HDB3 line encoding.
- RJ-45 female connector.
- Support for cable FC 2327 (PN 30L6572).
Note: | The cable you receive with your E1 Digital Modem Adapter is required for
Electromagnetic Compatibility (EMC) compliance.
|
This adapter plugs into any 6U CPCI adapter slot.
This adapter provides:
- Support for E1 line speed of 2.048 Mbps.
- Thirty 64-Kbps B-channels for data and one 64-Kbps D-channel for signaling
or thirty-one 64-Kbps time slots (31 DS0s) for channelized service.
- Selectable framing to FAS and CRC4 formats.
- Detection and generation of remote and AIS alarms.
- Generation of line build outs for a 120-ohm line.
- Two separate loopbacks for testing: payload and line. The
diagnostics program provides a local loopback, as well.
- Line error counters for bipolar and code violations, CRC4 code word
errors, FAS errors, and E-bits.
- B8ZI, AMI, and HDB3 line encoding.
- RJ-45 female connector.
- Support for cable FC 2327 (PN 30L6572).
Note: | The cable you receive with your E1 Digital Modem Adapter is required for
Electromagnetic Compatibility (EMC) compliance.
|
This adapter plugs into any 6U CPCI adapter slot.
Provides two ports that allow attachment of analog telephone handset or
analog fax machine to the IBM 2212.
This adapter plugs into any 3U CPCI adapter slot.
Provides two analog voice ports that allow attachment to analog central
office trunks.
This adapter plugs into any 3U CPCI adapter slot.
Provides two analog voice ports that provide analog PBX emulation for
attachment to private networks.
This adapter plugs into any 3U CPCI adapter slot.
This adapter allows up to four analog phone line connections. The
modems support the V.34 standard up to 33.6 Kbps as well as
K56Flex technology and the new V.90 ITU standard for speeds up to 56
Kbps. Transmit rates are limited to a maximum of 33.6
Kbps. Only asynchronous protocols, that is, dial-up PPP, are
supported.
The external interface for each modem is a RJ-11 connector.
This adapter plugs into any 3U CPCI adapter slot.
Provides a coprocessor with dedicated memory. When the software
begins to perform compression and encryption functions it uses the
coprocessor's memory to prevent a decline in performance. After
you install and enable this compression/encryption adapter in the IBM 2212 the
AIS software uses the coprocessor for compression and encryption packet
processing. This adapter provides:
- CDMF, DES, Triple-DES, RC4 encryption support
Note: | Encryption support is controlled by the AIS software and is subject to export
control. Before the compression/encryption adapter can be used for data
encryption you must download the version of the AIS software with data
encryption support. You can obtain this software at:
http://www.networking.ibm.com/support/downloads/2212
|
- LZS, and MPPC compression support
- 127/63 simultaneous full-duplex LZS/MPPC compression sessions
This adapter plugs into any 3U CPCI adapter slot.
Footnotes:
- 5
-
When speeds above 2.048 Mbps are used, only port number 1 on an adapter
can be clocked at this rate. Ports 2, 3, and 4 must be running at 64
Kbps or less.
[ Top of Page | Previous Page | Next Page | Table of Contents | Index ]